AQUAREA T-CAP H GENERATION - SPLIT SINGLE PHASE / THREE PHASE HEATING AND COOLING - SXC

Features-Advantages

- Stable operation at rated power down to -20°C
For new buildings or renovation
- Heating and cooling
Domestic hot water with external tank
For Radiators - Fan Coils - Underfloor Heating
- Wide range: From 9 to 16 kW
- Maximum heating supply temperature 60°C
- Cooling water temperatures from 5 to 20°C
- Operation in outdoor temperatures down to -28°C
Product label A++ (55°C), range A++ to G
System label A+++ (35°C), range A+++ to D
- Controller function as a room thermostat
- Optional control via smartphone (Aquarea Smart Cloud)

Panasonic-Aquarea-T-Cap

The Aquarea T-CAP Split series is the ideal solution for extreme outdoor conditions, providing stable power and performance down to -20°C.

The Aquarea T-CAP can operate at outdoor temperatures down to -28 °C , while ensuring stable operation at its rated output down to -20 °C . The pump control also functions as a thermostat for flexible and better management of heating and cooling. It can produce 60 °C heating water, making it the ideal solution for renovation projects as well. Its split form is ideal for homes with boiler rooms or small storage rooms and ensures uninterrupted operation of the hydraulic system.

Αντλία θερμότητας κατάλληλη για το πρόγραμμα Αλλάζω συσκευή

The Aquarea T-CAP Monobloc series is the ideal solution for extreme outdoor conditions, providing stable power and performance down to -20°C.

AQUAREA T-CAP J GENERATION - Monobloc Monobloc Monophase / Triphase HEATING AND COOLING - MXC

Features-Advantages

- Stable operation at rated power down to -20°C
Coolant R32
For new buildings or renovation
- Heating and cooling
Domestic hot water with external tank
For Radiators - Fan Coils - Underfloor Heating
- Wide range: From 9 to 16 kW
- Maximum heating supply temperature 60°C
- Cooling water temperatures from 5 to 20°C
- Operation in outdoor temperatures down to -28°C
Product label A++ (55°C), range A++ to G
System label A+++ (35°C), range A+++ to D
- Controller function as a room thermostat
- Optional control via smartphone (Aquarea Smart Cloud)

The Aquarea T-CAP can operate at outdoor temperatures down to -28 °C , while ensuring stable operation at its rated output down to -20 °C . The pump control also functions as a thermostat for flexible and better management of heating and cooling. It can produce 60 °C heating water, making it the ideal solution for renovation projects as well. Its monobloc form offers easy installation in new or existing installations.

Higher energy efficiency than others heating systems.

Whether in renovated or new buildings, T-CAP heat pumps are used where the demand for thermal power is high.

To ensure that the thermal capacity of the heat pump is maintained even at low temperatures

The Aquarea T-CAP series models are ideal for
to replace old gas boilers, or
oil, in combination with underfloor heating,
Radiators or Fan Coils

The heat pump converts heat energy outside into warmth inside

With the Aquarea Heat Pumps up to the 80% the required thermal energy is taken from the atmospheric air

Aquarea transfers the thermal energy from the ambient air to water for heating, cooling or Hot Water Use in your home.

Make sure that the heating capacity is maintained even at low temperatures.

The entire Aquarea T-CAP range is excellent for replacing gas or oil boilers and for connection to new underfloor heating, radiators or fan coil units. All Aquarea heat pumps can also be connected to a solar thermal or photovoltaic system to increase efficiency and minimise environmental impact.

Higher efficiency compared to other heating systems.

Panasonic heat pumps have a maximum COP of 4.85 at +7°C which makes them much more efficient than other heating systems.
The Aquarea T-CAP is also able to provide extremely high performance, regardless of the outside temperature or water temperature.

A larger heat pump is not needed to achieve the required heating at low temperatures.

Panasonic Aquarea T-CAP heat pumps can operate in outdoor temperatures down to -28°C and maintain their power without back-up resistance at -20°C*. With other heat pumps, more power is required to achieve the same level of comfort at low outdoor temperatures.

* Flow temperature 35°C.
Other heat pumps need electrical resistance to meet the demand of the house
The capacity of other heat pumps must be larger than PANASONIC Aquarea T-CAP heat pumps

The PANASONIC Aquarea T-CAP heat pump does not need a heater as the power remains constant even at -15°C. So there is no need to buy a larger heat pump

1. Power in kW
2. Other heat pump
3. Power required to heat the house
4. Poor performance at high power
5. - High flexibility with Panasonic Inverter compressors
- High performance even at part load

How Aquarea T-CAP maintains performance even at -20°C in outdoor conditions.

Thanks to the efficient control of the coolant through the unique two-pipe heat exchanger and bypass, the Aquarea T-CAP provides stable heating even at -20°C.

Two-pipe heat exchanger.
Low pressure and low temperature coolant in the inner tube.